JPDR(Japan Power Demonstration Reactor)

Dismantling of Facility Components and Demolition of Building Structures

For demolition of the JPDR, its components including the turbine generator, condenser, heat exchangers, and piping, which were slightly contaminated, were dismantled by workers using conventional methods and tools. Prior to demolition of the building, the surfaces of the concrete structure (wall, floor, and ceiling) were decontaminated and measurements were conducted to verify that no contamination remained on the surface. Demolition of the buildings of the turbine generator, nuclear reactor vessel, and the stack was conducted. All of the dismantling process was completed by FY1995, which concluded with leveling of the former building site.

Dismantling of the control room
Dismantling of the control room

Dismantling of the turbine generator
Dismantling of the turbine generator

Decontamination of the floor by shot blast
Decontamination of the floor by shot blast

Survey of surface radioactivity by detector
Survey of surface radioactivity by detector

Demolition of the turbine building
Demolition of the turbine building

Removal of the reactor building's steel roof
Removal of the reactor building's steel roof

Copyright(C) Japan Atomic Energy Agency. All Rights Reserved.