H. Hirayama*1,2, K. Kondo*1,2, S. Suzuki*1, Y. Tanimura*1, K. Iwanaga*1, H. Nagata*1
*1 Nuclear Regulation Authority
*2 High Energy Accelerator Research Organization
Investigation of main radiation source above shield plug of Unit 3 at Fukushima Daiichi Nuclear Power Station
EPJ Web of Conferences 153, 08010 (2017)
M. Kowatari, H. Zutz*1, O. Hupe*1
*1 Physikalisch-Technisch Bundesanstalt
Correction factors for attenuation and scattering of the wall of a cylindrical ionization chamber in the 6 MeV to 7 MeV high-energy photon reference field
Radiat. Prot. Dosimetry, Volume 178 (1), 48-56 (2018)
古渡 意彦
「中性子のつくりかた」第2章 RI中性子線源
波紋, volume 27 (3), 109-112 (2017)
谷村 嘉彦, 富田 純平, 吉富 寛, 吉澤 道夫, 箱崎 亮三*1, 高橋 荘平*1
*1 (一社)南相馬除染研究所
福島周辺の家屋内外におけるγ線スペクトルの評価
保健物理, Vol.51(3), 141-146 (2016)
T. Matsumoto*1, A. Masuda*1, H. Harano*1, Y. Shikaze, Y. Tanimura, H. Seito*2, S. Kurashima*2, S. Nishino, H. Yoshitomi, J. Nishiyama*3, M. Hagiwara*4, Y. Unno*1, M. Yoshizawa
*1 National Institute of Advanst Industrial Science and Technology
*2 National Institute of Quantum and Radiological Science and Technology
*3 Tokyo Institute of Technology
*4 High Energy Accelerator Research Organization
Development of the high-energy neutron fluence rate standard field in Japan with a peak energy of 45 MeV using the 7Li(p,n)7Be reaction at TIARA
Journal of Nuclear Science and Technology, 54(5), 529-538 (2017)
S. Nishino, Y. Tanimura, Y. Ebata*1, M. Yoshizawa
*1 Institute of Radiation Measurements
Development of the graphite-moderated neutron calibration fields using 241Am-Be sources in JAEA-FRS
Journal of Radiation Protection and Research, 41(3), 211-215 (2016)
H. Yoshitomi, M. Kowatari
Influence of different types of phantoms on the calibration of dosemeters for eye lens dosimetry
Radiation Protection Dosimetry, 170(1-4), 199-203 (2016)
H. Yoshitomi, M. Kowatari
Influence of the irradiation systems on beta-ray calibration for dosemeters
保健物理, Vol.51(3), 160-166 (2016)
上野 有美, 中川 雅博, 佐藤 淳也*1, 岩井 保則*2
*1 環境技術開発センター 基盤技術研究開発部
*2 量子科学技術研究開発機構 六ヶ所核融合研究所 ブランケット研究開発部
放射性気体廃棄物中の14C捕集に用いる疎水性パラジウム触媒の酸化性能評価
保健物理, Vol.51(1), 7-11 (2016)
富田 純平, 阿部 琢也
γ線スペクトロメトリーによる淡水中の低濃度ラジウム(Ra)同位体分析法−Powdex樹脂を用いた現地における大容量水試料の前処理及び硫酸バリウム共沈法の適用−
JAEA-Research 2016-026
川崎 将亜, 他16名
原子力施設等の緊急時における被ばく評価事例集
JAEA-Data/Code 2017-004
J. Tomita, M. Yamamoto*1, T. Nozaki, Y. Tanimura, T. Oishi
*1 Kanazawa University
Determination of low-level radiostrontium , with emphasis on in situ pre-concentration of Sr from large volume of freshwater sample using Powdex resin
Journal of Environmental Radioactivity, 146, 88-93 (2015)
M. Kowatari, T. Kubota*1, Y. Shibahara*1, T. Fujii*1, S.Fukutani*1, K. Takamiya*1, S. Mizuno*2, H. Yamana*1
*1 Kyoto University
*2 Fukushima Prefecture
Application of a CZT detector to in-situ environmental radioactivity measurement in Fukushima area
Radiation Protection Dosimetry, 167, 348-352 (2015)
M. Kowatari, Y. Tanimura
Establishment of 6 to 7 MeV high-energy gamma-ray calibration fields produced using the 4 MV Van de Graaff accelerator at the Facility of Radiation Standards, Japan Atomic Energy Agency
Radiation Protection Dosimetry, 168(3), 300-313 (2016)
A. Masuda*1, T. Matsumoto*1, H. Harano*1, Y. Tanimura, Y. Shikaze*2, H. Yoshitomi, S. Nishino, S. Kurashima*3, M. Hagiwara*4, Y. Unno*1, J. Nishiyama*1, M. Yoshizawa, H. Seito*3
*1 National Institute of Advanced Industrial Science and Technology
*2 JAEA, Fukushima Environmental Safety Center
*3 JAEA, Takasaki Advanced Radiation Research Institute
*4 High Energy Accelerator Research Organization
Time-of-flight measurements for low-energy components of 45 MeV quasi-monoenergetic high-energy neutron field from 7Li(p,n) reaction
IEEE transactions on Nuclear Science, 62(3), 1295-1300 (2015)
上野 有美, 中川 雅博, 佐藤 淳也*1, 岩井 保則*2
*1 核燃料サイクル工学研究所 環境技術開発センター 基盤技術研究開発部 廃棄物処理技術グループ
*2 六ヶ所核融合研究所 ブランケット研究開発部 トリチウム工学研究グループ
放射性気体廃棄物中の14C捕集に用いる疎水性パラジウム触媒の酸化性能評価
保健物理, Vol.51, 7-11 (2016)
Hiroshi Yoshitomi, Yosuke Tatebe, Keiichi Kawai and Munehiko Kowatari
Practice for reducing contamination of controlled area under the influence of Fukushima nuclear accident
Progress in Nuclear Science and Technology, Volume 4, 81-84 (2014)
Yoshihiko Tanimura, Katsutoshi Fujii, Masahiro Tsutsumi and Michio Yoshizawa
Neutron fluence monitoring system in mono-energetic neutron fields at FRS / JAEA
Progress in Nuclear Science and Technology, Volume 4, 388-391 (2014)
Yoshihiko Tanimura, Masahiro Tsutsumi and Michio Yoshizawa
Determination of neutron fluence in 1.2 and 2.5 MeV mono-energetic neutron calibration fields at FRS / JAEA
Progress in Nuclear Science and Technology, Volume 4, 392-395 (2014)
M.Kowatari, Y.Tanimura, M.Tsutsumi
Measurement of air kerma rates for 6- to 7-MeV high energy gamma-ray field by ionization chamber and build-up plate
Radiation Protection Dosimetry, 162 (4), 446-458 (2014)
Y.Tanimura, M.Tsutsumi and M. Yoshizawa
Development of portable long counter with two different moderator materials
Radiation Protection Dosimetry, 161 (1-4), 144-148 (2014)
Y.Tanimura, M.Tsutsumi and M. Yoshizawa
Photon dose mixed in monoenergetic neutron calibration fields using 7Li(p,n)7Be reaction
Radiation Protection Dosimetry, 161 (1-4), 149-152 (2014)
M.Kowatari, Y.Tanimura and M.Yoshizawa
An attempt to decrease anisotropic emissions of neutrons from a cylindrical 241Am-Be-encapsulation source
Radiation Protection Dosimetry, 161 (1-4), 166-170 (2014)
山本 政儀*1, 富田 純平
*1 金沢大学
放射能と温泉
温泉科学, Vol.64, 388-401 (2015)
鈴木 朗史, 他5名
外部被ばく個人線量測定用OSL線量計の諸特性
JAEA-Technology 2014-049
中川 雅博
呼吸追随型電動ファン付全面マスクの防護性能試験
保健物理, Vol.47(3), 189-193 (2012)
小沼 勇
表面汚染検査計シミュレーションソフトの利用とその効果
保健物理, Vol.47(3), 194-197 (2012)
津田 修一*1, 堤 正博
*1 原子力機構 原子力基礎工学研究部門
種々の大きさのCsI(Tl)シンチレーション検出器のγ線に対するスペクトル-線量換算演算子(G(E)関数)の計算と評価
保健物理, Vol.47(4), 260-265 (2012)
川崎 将亜
環境試料中放射性ストロンチウム分析法の改善
保健物理, Vol.47(2), 124-129 (2012)
M. Matsuda, T. Asozu, M. Sataka, A. Iwase
Mono-energetic Neutron Fields Using 4 MV pelletron Accelerator at FRS / JAEA
Proceedings of the IAEA Technical Meeting on Use of Neutron Beams for High Precision Nuclear Data Measurements, IAEA-F1-TM-42752, 1-6 (2013)
大倉 毅史, 他12名
原子力科学研究所における福島第一原子力発電所事故下での環境放射線及び大気中放射性核種の緊急時モニタリング
JAEA-Data/Code 2012-010, (2012)
宮内 英明
指先の被ばく線量評価の信頼性を向上-光刺激ルミネセンス(OSL)型リングバッジの開発-
2012年 成果普及情報誌「未来を拓く原子力」p.111
大倉 毅, 他12名
原子力研究所における福島第一原子力発電所事故下での環境放射線及び大気中放射性核種の緊急時モニタリング
JAEA-Data/Code 2012-010, (2012)
D. Maki*1, F. Sato*1, I. Murata*1, Y. Kato*1, Y. Tanimura, T.Yamamoto*2, T. Iida*1
*1 Osaka University
*2 Chiyoda Technol Corporation
Development of neutron-sensitive glass dosimeter containing isotopically enriched boron
Radiation Measurements, 46, 1484-1487 (2011)
T. Itoga*1, Y. Asano*1, Y. Tanimura
*1 SPRING-8
Response function of a superheated drop neutron monitor with lead shell in the thermal to 400-MeV energy range
Radiation Protection Dosimetry, 146, 96-99 (2011)
谷村 嘉彦
原子力機構・放射線標準施設棟に単色中性子校正場が完成
放計協ニュース No.47 2-3 (2011)
Y. Shikaze, Y. Tanimura, M. Tsutsumi, H. Nemoto, Y. Yoshizawa, H. Harano*1, T. Matsumoto*1, K. Mizuhashi*2
*1 AIST
*2 JAEA. Takasaki Advanced Radiation Research Institute
Improvement of Measurement System for Source Neutron Spectrum to extend the Energy Range down to a few MeV
JAEA-Review 2011-043, 146 (2012)
F. Saito, J. Koarashi, O. Kurihara, E. Kim
An Imaging Plate Technique for Evaluating Energy Attenuation in Evaporated Samples with Different Surface Conditions
Radiation Protection Dosimetry, 139(4), 584-589 (2010)
Y. Tanimura, M. Tsutsumi, J. Saegusa, Y. Shikaze, M. Yoshizawa
Evaluation of target photon dose mixed in mono-energetic neutron fields using 7Li(p,n)7Be reaction
Radiation Measurements, 45, 1163-1166 (2010)
H. Harano*1, T. Matsumoto*1, Y. Tanimura, Y. Shikaze, M. Baba*2, T. Nakamura*2
*1 AIST
*2 Tohoku University
Monoenergetic and quasi-monoenergetic neutron reference fields in Japan
Radiation Measurements, 45, 1076-1082 (2010)
Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi, Y. Uchita, M. Yoshizawa
Development of the Quasi-monoenergetic Neutron Calibration Fields of Several Tens of MeV at TIARA
Progress in Nuclear Science and Technology, Vol.1, 166-169 (2011)
M. Kowatari, H. Dombrowski*1, S. Neumaier*1
*1 PTB
Monte Carlo simulations of the photon calibration fields at the underground laboratory of PTB
Radiation Protection Dosimetry, 142(2-4), 125-135 (2010)
大倉 毅史, 山澤 弘実*1, 森泉 純*1, 平尾 茂一*1, 飯田 孝夫*1
*1 名古屋大学
八丈島における222Rn散逸率の評価とその大気中濃度への影響
保健物理, VoL.45(3), 270-277 (2010)
谷村 嘉彦
連載講座 電力・エネルギー関連分野における最近の計測システム 第11回 放射線計測
電気評論, 95-5, 61-66 (2010)
谷村 嘉彦
世界に誇る高性能単色中性子標準照射場が完成‐中性子利用のための技術的基盤が確立‐
原子力eye, 57-2, 37-40 (2011)
清水 滋
β線線量当量測定器の校正方法に関するJIS化について
放計協ニュース No.45 (2010)
宮内 英明, 吉富 寛, 佐藤 義高, 橘 晴夫, 高橋 史明*1
*1 原子力機構 原子力基礎工学研究部門
OSL型リングバッジの開発
JAEA-Technology 2010-050
清水 滋, 藤井 克年, 川崎 朋克*1
*1 大洗研究開発センター 安全管理部
放射線測定器の性能試験に用いる国内規格に準拠した軟X線標準場の整備
JAEA-Technology 2010-005 (2010)
清水 滋, 澤畠 忠広, 梶本 与一, 志風 義明, 吉原 泰明*1, 立部 洋介
*1 放射線計測協会
放射線測定器の性能試験に用いる国内規格に準拠した中硬X線標準場の整備
JAEA-Technology 2010-009 (2010)
Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi, Y. Uchita, Y. Yoshizawa, H. Harano*1, T. Matsumoto*1, K. Mizuhashi*2
*1 AIST
*2 JAEA. Takasaki Advanced Radiation Research Institute
Establishment of Neutron Fluence Monitoring Techniques for Quasi-monoenergetic Neutron Calibration Fields of High Energy at TIARA
JAEA-Review 2010-065, 158 (2011)
Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi
Development of highly efficient proton recoil counter telescope for absolute measurement of neutron fluences in quasi-monoenergetic neutron calibration fields of high energy
Nuclear Instruments and Methods in Physics Research A, 615, 211-219 (2010)
M. Takahashi, S. Kinase, R. Kramer*1
*1 Universidade Federal de Pernambuco
Evaluation of Counting Efficiencies of a Whole-body Counter Considering the ICRP Biokinetic Models
Proceedings of the Sixteenth EGS User's Meeting in Japan, KEK Proceedings 2009-7, 78-83 (2009)
清水 滋
日本の放射線(能)測定の信頼性向上に貢献する放射線標準施設
第1回(平成20年度)「原子力歴史構築賞」パンフレット, 日本原子力学会, (2009年11月)
Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi, Y. Uchita, Y. Yoshizawa, H. Haran*1, T. Matsumoto*1, H. Kaneko*2
*1 AIST
*2 JAEA. Takasaki Advanced Radiation Research Institute
Development of a Transmission Type Fluence Monitor for Quasi-monoenergetic Neutron Calibration Fields of Several Tens of MeV
JAEA-Review 2009-041, 152 (2009)
谷村 嘉彦
中性子測定器のkeV領域での正確な感度測定を実現-加速器を利用したkeV領域単色中性子校正場の開発-
未来を拓く原子力 2009, 105 (2009)
Y. Tanimura
High Precision Calibration of Neutron Detectors in keV Region -Development of keV Region Mono-Energetic Neutron Calibration Fields Using an Accelerator-
JAEA R&D Review 2009, 105 (2010)
M.Takahashi,M.Sekiguchi,H.Miyauchi,H.Tachibana,M.Yoshizawa,T.Kato*1,A.Yamaguchi*1
*1 ALOCA CO., LTD
Performance of the Hp(10) and Hp(0.07) Measurable Electronic Pocket Dosimeter for Gamma- and Beta-Rays
Supplement to the Journal of Nuclear Science and Technology, 5, 225-228 (2008)
Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi, S. Shimizu, Y. Yoshizawa, Y. Yamaguchi
Development of the Neutron Calibration Fields using Accelerators at FRS and TIARA of JAEA
Journal of Nuclear Science and Technology, Supplement 5, 209-212 (2008)
M. Kowatari, K. Fujii, M. Tsutsumi, B.H. Kim*1, K.C. Lee*1, M. Yoshizawa, Y. Yamaguchi
*1 Korea Atomic Energy Research Institute
An Inter-comparison of the Neutron Calibration Field using D2O Moderated 252Cf Source at JAEA and KAERI
Journal of Nuclear Science and Technology, Supplement 5, 217-220 (2008)
J. Saegusa
CREPT-MCNP Code for Efficiency Calibration of HPGe Detectors with the Representative Point Method
Applied Radiation and Isotopes, 66, 774-779 (2008)
大倉 毅史, 山澤 弘実*1, 森泉 純*1, 平尾 茂一*1, 郭 秋菊*2, 遠嶋 康徳*3, 飯田 孝夫*1
*1 名古屋大学
*2 北京大学
*3 国立環境研究所
東アジア域における大気中222Rn濃度連続測定ネットワークと洋上の孤島における大気中222Rn
大気環境学会誌, 44, 42-51 (2008)
古渡 意彦, 小沼 勇, 谷村 嘉彦, 川崎 克也, 三枝 純, 吉澤 道夫
241Am-Be中性子線源からの中性子放出の非等方係数の決定
Radioisotopes, 57, 559-569 (2008)
谷村 嘉彦, 美留町 厚, 吉田 真, 渡辺 鐶*1
*1 名古屋大学 名誉教授
簡易型放射線測定器に利用するための半導体放射線検出素子の性能評価
Radioisotopes, 57, 733-738 (2008)
高橋 聖, 他10名*1
*1 日本保健物理学会 ICRP新消化管モデル専門研究会
ICRP新消化管モデル専門研究会報告書(1) ~Publ.100の解説~
日本保健物理学会専門研究会報告書シリーズ, Vol.6 No.2
山本 英明, 古田 定昭*1, 宮崎 振一郎*2, 宮越 順二*3
*1 核燃料サイクル工学研究所 放射線管理部
*2 関西電力
*3 弘前大学
クリアランスを巡る最近の動きについて~クリアランスの運用状況及びICRPの新勧告~
Isotope News, 649, 64-68 (2008)
谷村 嘉彦, 佐藤 達彦*1, 熊田 博明*2, 照沼 利之*3, 榮 武二*3, 原野 英樹*4, 松本 哲郎*4, 鈴木 敏和*5, 松藤 成弘*5
*1 原子力機構 放射線防護研究Gr
*2 原子力機構 研究炉技術課
*3 筑波大学
*4 産業技術総合研究所
*5 放射線医学総合研究所
「中性子場の線量評価~測定原理から医療応用まで~」議論のまとめ
放射線, 34-2, 135-139 (2008)
吉澤 道夫
国連科学委員会(UNSCEAR)最新情報
長瀬ランダウア NLだより, No.371 (2008年11月)
吉澤 道夫
連載講座「放射線防護に用いる線量概念について」第4回 被ばく線量モニタリングのための実用量について
保健物理, 44(1), 36-45 (2009)
志風 義明
高エネルギー中性子校正場について
放計協ニュース, No.42, 2008.10
Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi, Y. Yoshizawa, H. Harano*1, T. Matsumoto*1, H. Kaneko*2
*1 AIST
*2 JAEA. Takasaki Advanced Radiation Research Institute
Evaluation of the Performance of a New Fluence Monitor for Quasi-monoenergetic Neutron Calibration Fields of Several Tens of MeV Range
JAEA-Review 2008-055, 166 (2008)
J. Saegusa
CREPT-MCNP 1.1 (Calibration Code for the Representative Point Method with MCNP); User Manual, Version 1.1.0
JAEA-Data/Code 2008-017 (2008)
http://jolissrch-inter.tokai-sc.jaea.go.jp/pdfdata/JAEA-Data-Code-2008-017.pdf
Y.Tanimura, J.Saegusa, Y.Shikaze, M.Tsutsumi, S.Shimizu, M.Yoshizawa
Construction of monoenergetic neutron calibration fields using 45Sc(p,n)45Ti reaction at JAEA
Radiation Protection Dosimetry, 126, 8-12 (2007)
M.Kowatari, K.Fujii, M.Takahashi, M.Yoshizawa, S.Shimizu, K.Kawasaki, Y.Yamaguchi
Evaluation of the characteristics of the neutron reference field using D2O-moderated 252Cf source
Radiation Protection Dosimetry, 126, 138-144 (2007)
Y.Shikaze, Y.Tanimura, J.Saegusa, M.Tsutsumi, Y.Yamaguchi, Y.Uchita*1
*1 Institute of Radiation Measurements
Investigation of properties of the TIARA neutron beam facility of importance for calibration applications
Radiation Protection Dosimetry, 126, 163-167 (2007)
吉澤 道夫
原子放射線の影響に関する国連科学委員会(UNSCEAR)第55回会合に出席して
放影協ニュース, No.52 (2007年7月)
清水 滋
原子力機構・放射線標準施設の施設共用の開始について
放計協ニュース, No.39, 2007.5
三枝 純
代表点法を用いた放射能測定器の効率校正
日本放射線安全管理学会誌, 6(2), 39 (2007)
谷村 嘉彦
5.4 放射線計測
エネルギーレビュー, 2007-7, 25-27 (2007)
谷村 嘉彦, 美留町 厚
低価格・ハンディ型の簡易放射線メータ
エネルギーレビュー, 2007-7, 25-27 (2007)
Y.Shikaze, Y.Tanimura, J.Saegusa, M.Tsutsumi, Y.Yamaguchi, H.Harano*1, T.Matsumoto*1, H.Kaneko*2
*1 AIST
*2 JAEA. Takasaki Advanced Radiation Research Institute
Development of a detector for absolute measurement of neutron fluence in quasi-monoenergetic neutron calibration fields of high energies
JAEA-Review 2007-060, 189 (2008)
Y.Watanabe, S.Kinase, K.Saito
Evaluation of Absorbed Doses for Photon and Electron to the Urinary Bladder Wall Considering Radiosensitive Cells
Radioisotopes, 55, 719-725 (2006)
J.Koarashi, F.Saito, K.Akiyama, N.M.Rahman*1, T.Iida*1
*1 Nagoya University
A new digital autoradiographical method for identification of Pu particles using an imaging plate
Applied Radiation and Isotopes 65(4), 413-418 (2007)
N.M.Rahman*1, T.Iida*1, F.Saito, J.Koarashi, K.Yamasaki*2, H.Yamazawa*1, J.Moriizumi*1
*1 Nagoya University
*2 Kyoto University(Research Reactor Institute)
Evaluation of aerosol sizing characteristic of an impactor using imaging plate technique
Radiation Protection Dosimetry 123(2), 171-181 (2007)
吉澤 道夫
第54回国連科学委員会(UNSCEAR)会合に出席して
保健物理, 41(3), 128-130(2006)
山口 恭弘
外部被ばく換算係数
放射線科学, 49(9), 311-319 (2006)
山口 恭弘
OECD/NEA主催「放射線防護体系の進展に関する第3回アジア地域会議」について
放影協ニュース, (49), 11-13 (2006)
藤井 克年, 古渡 意彦, 川崎 克也
日本原子力研究開発機構・放射線標準施設 4MVファン・デ・グラーフ加速器の設置から運用まで(放射線管理コーナー)
保健物理, 41(3), 175-179 (2006)
三枝 純
英国国立物理学研究所(NPL)における中性子標準の現状
放計協ニュース, 37, 2-3 (2006)
三枝 純
種々形状の体積試料に含まれる放射能を迅速に決めるための技術を開発する -代表点法を用いた放射能測定器の効率校正-
未来を拓く原子力 -原子力機構の研究開発成果-, 創刊号, 135, 日本原子力研究開発機構 (2006)
J. Saegusa
"Representative point calibration method" for efficiency calibration of radioactivity measuring instrument -Development of a method for determining radioactivity in samples in various shapes-
JAEA R&D Review 2006, 1, 135 (2007)
藤井 克年, 川崎 克也, 古渡 意彦, 谷村 嘉彦, 梶本 与一, 清水 滋
放射線標準施設棟 加速器マニュアル
JAEA-Testing 2006-005 (2006)
http://jolissrch-inter.tokai-sc.jaea.go.jp/pdfdata/JAEA-Testing-2006-005.pdf
三枝 純, 谷村 嘉彦, 吉澤 道夫
長軸型反跳陽子比例計数管の開発および144, 250, 565 keV単色中性子校正場のフルエンス絶対測定
JAEA-Research 2006-065 (2006)
三枝 純
代表点校正法を用いた放射能測定器の効率校正用コード CREPT-MCNP
JAEA-Data/Code 2006-027 (2007)
http://jolissrch-inter.tokai-sc.jaea.go.jp/pdfdata/JAEA-Data-Code-2006-027.pdf
A. Endo, T. Sato, D. Satoh, Y. Shikaze, Y. Tanimura, J. Saegusa, M. Tsutsumi, Y. Yamaguchi, H. Kaneko, K. Oda*1, Y. Imasaka*1, M. Notsu*1, H. Tada*1, H. Tawara*2, K. Eda*2, K. Takahashi*2, M. Baba*3
*1 Kobe University
*2 KEK
*3 Tohoku University
Development of Monitor and Dosimeter Applicable to High-Energy Neutrons
JAEA-Review 2006-042, 182 (2007)
M. Tsutsumi
Strategy on Quality Assurance in Radiation Fields and Calibration Techniques at FRS of JAEA
JAEA-Conf 2007-002, 132-138 (2007)
Y. Watanabe, J. Kuwabara
Ultraviolet photolysis of urine for suppression of color quenching prior to liquid scintillation counting of tritium
Analytical & Bioanalytical Chemistry, 384(2), 547-550 (2006)
K. Yamasoto, M. Tsutsumi, T. Oishi, M. Yoshizawa, M. Yoshida
CsI(Tl)/plastic phoswich detector enhanced in low-energy gamma-ray detection
Nuclear Instruments and Methods in Physics Research A, 550,609-615, (2005)
Y. Tanimura, J. Saegusa, M. Yoshizawa, M. Yoshid
Design of a single moderator-type neutron spectrometer with enhanced energy resolution in the energy range from a few to 100 keV
Nuclear Instruments and Methods in Physics Research, A547, 92-600 (2005)
M. Tsutsumi, Y. Tanimura
LaCl3(Ce) scintillation detector applications for environmental gamma-ray measurements of low to high-dose rates
Nuclear Instruments and Methods in Physics Research, A557(2), 554-560 (2006)
Y. Tanimura, Y. Uchita*1, J. Saegusa, M. Yoshizawa
*1 Institute of Radiation Measurements
Recent Activities on Neutron Calibration Fields at FRS of JAERI
http://www.bipm.org/cc/CCRI(III)/Allowed/16/CCRI(III)05-07.pdf
吉澤 道夫
中性子線量計の校正方法の標準化について
FB News, No.342 (2005年6月)
野口 正安*1, 吉澤 道夫
*1:キャンベラジャパン(株)
第2章 放射線の測定
放射線安全管理の実際, (社)日本アイソトープ協会 (2006年3月)
山口 武憲, 吉澤 道夫
第3章 被ばく線量の測定と評価
放射線安全管理の実際, (社)日本アイソトープ協会 (2006年3月)
松浦 賢一, 橘 晴夫
環境放射線リアルタイム監視システム
電気評論, 第90巻第7号, 43-46 (2005)
Y. Shikaze, Y. Tanimura, Y. Uchita, J. Saegusa, Y. Yamaguchi
Evaluation of the property for quasi-monoenergetic neutron calibration fields of high energies at TIARA
JAEA-Review 2005-001, 337-339,(2006)